Fixable without opening the unit
A dead thermostat, a tripped breaker, or a blown low-voltage fuse can all stop a heat pump cold. These get sorted out fast once someone who knows the system checks them in order.

The right pro for this job
A heat pump that won't start could be stuck on a dead thermostat, a tripped breaker, or something inside the unit itself. In most Colorado homes it's working alongside a gas furnace, so it helps to know whether the problem is the heat pump or how the two systems are talking to each other. Below are the usual causes, and a way to get a local contractor who works on heat pumps all year to take a look.
Match me with a proA heat pump that won't turn on usually comes down to power, the thermostat, or a safety switch doing what it's supposed to do. Start with the breaker. Heat pumps run on 240 volts and share the panel with other big loads, so a tripped breaker is common and easy to miss. If the breaker is fine, check the thermostat has power and is calling for heat or cool, not just sitting blank. Many outdoor units also have a disconnect box mounted on the wall right next to them, and if that switch got bumped or left open after prior service, the unit gets no power at all even though everything inside the house looks normal. Some systems also have a float switch near the indoor coil that shuts the unit down if the drain line backs up, which stops it from running even though nothing looks broken from outside. In Colorado, most homes pair the heat pump with a gas furnace, so the furnace may still be heating even while the heat pump itself stays dead, which can delay noticing the problem.

August, and the air outside hasn't cooled off since noon. You're on top of the sheets because anything else is too much. The window's open but it isn't helping, just letting the warm air sit in the room with you. Somewhere around one in the morning you give up and go check the thermostat in the hall, and it's still set where you left it, still not answering. You can hear the dry Colorado wind outside but nothing from the unit. Back in bed the sheets are damp where you were lying. You check your phone, put it face down, and lie there waiting for the room to do something it isn't going to do tonight.


A heat pump looks like one machine, but it's really several systems checking each other before anything spins. The reversing valve is what lets it switch between heating and cooling by redirecting refrigerant flow, and if it sticks halfway, the control board often reads that as a fault and shuts everything down rather than guess. Outside, a defrost board watches the coil temperature through a sensor. If that sensor reads wrong, the board can think the coil is frozen over when it's fine, and hold the unit in defrost or refuse to start it at all. Refrigerant charge matters too. Run low, and the low-pressure switch trips on purpose, since a compressor pumping refrigerant that isn't there will burn itself out fast. The start capacitor gives the compressor the initial push to get moving. Weak or dead, you get a hum, a click, or nothing, because the motor never gets that push. Some systems also count short cycles, those quick on-off bursts, and after enough of them in a row they lock out entirely until that counter gets reset. And between the thermostat and the outdoor unit runs a low-voltage wire carrying the signal that tells the compressor to run. A break or a short anywhere along that wire, and the command never arrives. Any one of these can look identical from inside the house: the thermostat calls for heat or cool, and nothing happens outside. Figuring out which one it is means checking voltage, pressure, and sensor readings in the right order, not guessing at parts.


A heat pump that won't start in January is a different problem than one that quits in July, and in Colorado you get both kinds of weather hard. When yours sits dead and the gas furnace is carrying the house, it's easy to let it wait, but a heat pump that won't engage on a mild fall day is worth finding out about before you need it on a cold one. The breaker, the thermostat, the reversing valve, the defrost board: any of these can be the reason, and sorting out which one takes someone who works on heat pumps paired with gas furnaces regularly, not just central air. That's the setup in most homes around here, and it changes where a tech looks first. Requesting a match puts this in front of one licensed contractor local to you, someone who sees this exact pairing all season, rather than scattering the same call across several companies and waiting to see who answers.

Colorado's dry heat means the outdoor unit works harder to move warmth than it would somewhere humid, since it's pulling on thinner air. That unit sits outside through hailstorms, dust, and whatever the wind carries off the plains. A fan motor or sensor that would last years in a mild climate can wear down faster out there. When the unit won't start, that outdoor half is usually where a contractor checks first, not the indoor coil.

Most homes here pair the heat pump with a gas furnace, and that pairing adds a layer the thermostat has to manage. The system has to decide which one runs, and that decision happens through a control board most homeowners never see. If the board is set wrong or a wire linking the two systems comes loose, the heat pump can sit idle while the furnace quietly takes over, and nothing on the thermostat will tell you why.
At 15.69 cents per kilowatt-hour, running a heat pump that's cycling wrong or short-cycling costs more than it should, even before it quits altogether. A unit that won't start at all isn't running up your bill, but once it's fixed, how well it runs decides what you pay from then on.
EIA-861 2025 statewide residential average




A dead thermostat, a tripped breaker, or a blown low-voltage fuse can all stop a heat pump cold. These get sorted out fast once someone who knows the system checks them in order.
A bad capacitor, a stuck contactor, or a failed control board won't show from outside. It takes someone who works on heat pumps regularly to find which part failed and replace it.

Whatever stopped your heat pump, it's one of the things covered above: a breaker, a thermostat, a safety switch doing its job, or a part inside the cabinet that's worn out or failed. None of that gets sorted out by guessing, and with a gas furnace carrying the house, it's easy to put off finding out which one it is.
Someone who works on heat pumps in Colorado through both the dry summer heat and the cold months knows which of these fail most and in what order to check them. When you request service through this page, you're matched with one licensed local contractor who takes on jobs like yours, not a handful of companies competing for your call. They'll reach out to look at your unit and tell you straight what's wrong with it.


A local pro for your heat pump repair